SEER2 vs SEER: Why You Should Not Convert Them
Classic AmericaNov 25th 20263 min read

The short answer
- SEER2 vs SEER is a change in the test, not just a nickname. SEER2 uses the DOE M1 procedure that took effect for new equipment in 2023. That test uses higher external static pressure, so the SEER2 number is usually lower than the old SEER on the same machine.
- There's no single multiplier that turns SEER into SEER2. A chart that says “subtract 1” or “multiply by 0.95” is just a guess.
- Our published SEER2 ratings: 23 (9,000), 19 (12,000 at a full 12,000 BTU/h, up to about 550 sq ft), 17 (11,500 BTU/h, up to about 550 sq ft), and 24 non-ducted on DUET.

What changed in the test
SEER is seasonal cooling output divided by seasonal watt-hours. Our article on what the older SEER number measured covers the original version of that idea. SEER2 keeps the seasonal idea but changes the lab conditions, including the external static pressure the blower is tested against. Since the test got tougher, a unit’s SEER2 rating won't match its old SEER rating. Comparing a 2018 SEER 20 box with a 2024 SEER2 20 box as if they had the same score gets both of them wrong.
| System | What the sheet says | Use it as |
|---|---|---|
| 9,000 BTU | 23 SEER2 · 12.5 EER2 | SEER2 |
| 12,000 · 19 SEER2 | 19 SEER2 · 10 EER2 · up to 550 sq ft | SEER2 |
| 12,000 class · 17 SEER2 | 17 SEER2 · 9.5 EER2 · up to 550 sq ft | SEER2 |
| DUET | 24 SEER2 non-ducted | SEER2 |
| 24,000 BTU | 17 SEER2 · 9.5 EER2 · HSPF2 9.5 | SEER2 |
What is a good SEER2 rating?
For split-system heat pumps, the federal minimum that took effect January 1, 2023 is 14.3 SEER2 and 7.5 HSPF2. The rules for cooling-only central air conditioners vary by region (13.4 SEER2 in the North, 14.3 in the Southeast and Southwest). A mini split heat pump is held to the heat-pump minimum. In our lineup, 17 SEER2 is already above 14.3, and 19 and 23 are higher still. DUET’s non-ducted 24 is the highest SEER2 we publish.
“Good” doesn't always mean “highest.” A 23 SEER2 9,000 BTU head is the wrong pick for a room that needs the 24,000 BTU system, and a 24 SEER2 two-head system is the wrong pick for one small bedroom. Whether the next step up pays for itself depends on how many hours you'll run it, and the Energy Savings Calculator can do that math for you.
From the spec sheet
- 18,000 BTU/h cooling · 1.5 tons
- 24 SEER2, non-ducted
- 208/230V
- Two 9,000 BTU indoor heads on one outdoor unit
- Heating nameplate 20,000 BTU/h
From the spec sheet
- 9,000 BTU/h cooling · 0.75 ton
- 23 SEER2
- 115V
- Up to 400 sq ft
- Heating nameplate 9,500 BTU/h
Please don't convert the 24,000 BTU sheet
- The 24,000 BTU model is rated 17 SEER2. That's the SEER2 rating printed on its spec sheet, not a conversion from an older SEER 18, and another model’s SEER2 doesn't carry over to it.
- DUET’s 24 SEER2 doesn't carry over to any other model.
- HSPF and HSPF2 are the heating versions of this same issue, so don't mix them up either.
- Efficiency doesn't change who should install the system. Refrigerant and electrical work are jobs for licensed pros, and you're covered for 5 years on the compressor and 1 year on parts.
A higher SEER2 pays back only if the hours are there. The Energy Savings Calculator compares the bill. The model comparison lines up the sheets.
Read the label that matches the model year
If two boxes were tested under different rules, pause the comparison and look up the current spec sheets. Our model comparison puts all our published figures in one grid, and the Size Finder still picks the BTU. A higher SEER2 on the wrong size isn't a bargain.
FAQ
Common questions
What is the difference between SEER and SEER2?
SEER2 is the M1 test used for equipment built to the 2023 standard. Its number is usually lower than the old SEER for the same equipment, so the two aren't interchangeable.
How do you convert SEER to SEER2?
You can't, with a single factor. Go by the rating printed for the test the unit was certified under. The 24,000 BTU model is already rated 17 SEER2, so there's no need to convert an older SEER number.
What is a good SEER2 rating for a mini split?
Anything above the federal minimum for split heat pumps, which is 14.3 SEER2. In our catalog, the published figures are 17, 19, 23, and 24 non-ducted on DUET. Just be sure to match the BTU first.